Shanghai Rotorcomp Screw Compressor Co., Ltd.
  • Rotary Screw Compressor Historical well-known manufacturer producing quality screw compressor,oil free compressor,high pressure compressor in ISO,TUV,CE certificates with good price, 5 years warranty, patented unique design, more energy-saving , reliable compressor system for al Rotary Screw Compressor
  • Oil Free Compressor Shanghai rotorcomp screw compressor offer 100% clean oil free air compressor that can be made in air cooled &water cooled, we can customize according to the special requests, and OEM service... Oil Free Compressor
  • Air Treatment Systems After-processing equipment of compressorISO,CE,TUV,ASME standard manufacturer producing quality Refrigerated air dryer,Desiccant air dryer, precised pipe filter from 1micron to 0.001micron, active-car... Air Treatment Systems
  • Diesel Movable Screw Compressor Diesel movable screw compressorReliable diesel portable screw compressor manufacturer producing quality diesel screw compressor from 50cfm--1600cfm@100psi-500psi in ISO,TUV,CE certificates with good p... Diesel Movable Screw Compressor
  • Screw Air End SCREW AIR ENDWorld-top Rotorcomp compact air screw compressor with best efficient in smaller demension in ISO,TUV certificates, 5 years warranty.Rotorcomp oil-injected screw air ends create the heart ... Screw Air End
CONATCT
Tel: +86-021-67150020
Fax: +86-021-67150020
Add: No.28 Minta Road, Songjiang District Shanghai, China
code

Common Electric Failure and Causes

This Fault Review of screw air compressor
Failure stop caused by the external parts of controllers may be removed by checking THIS FAULT or HISTORY FAULT, the method is shown as below:
Common electric failure and causes



FAILURE

CAUSES

MEASUREMENT TO TAKE

Air Exhaust Temperature too high

Bad vent condition, Oil lacking etc.

Check the vent condition and lubricant amount etc.

Temperature Sensor Failure

Cable off or PT1OO damaged

Checking the wiring and PT100

Over Pressure

The pressure too high or the pressure sensor failure

Check the pressure and the pressure sensor

Pressure Sensor Failure

Cable off, Sensor damaged or the cable connected reversed

Check the wiring and sensor transformer

Water Lacking

Water Pressure switch damaged

Check the water pressure switch

Phase Lacking

Power phase lacking or the Contactor terminal damaged

Check the power and contactors

Overloaded

Voltage too low, tubes blocked, Bearing Wear off or other mechanical failure or wrong set data etc.

Check the set data, Voltage, bearings, tubes and other mechanical systems.

Unbalance

Power unbalance, Contactor damaged or the internal open of the motor

Check the power, contactors and the motor

Rotor Lock

Voltage too low, tubes blocked, Bearing Wear off or other mechanical failure or wrong set data etc.

Check the set data, Voltage, bearings, tubes and other mechanical systems.

Short Circuit

Wrong Wiring, Incorrect Data setting etc.

Checking the wiring and set the data correctly

Wrong Phase Sequence

Reversed Phase sequence or phase off

Check the wiring

Fan stopped

Fan damaged, Contactor damaged, no control output

Check the wiring and control output

Overload or Rotor locking during starting process

Host start time set to a value less than the star angel time delay

Reset the host starting time to be longer than star angel delay + Load delay time

The main Contactor activate time to time

The emergency button loose

Check the wiring